Re: JVC GRD70 - CONDENSATION

Rexdreamer Posted Jan 18, 2006, in response to:Jockstraps

Jockstraps I have seen alot of the GR-d30,70 and 90's, here lately with that same problem, the fix falls between the dew sensor and the pre mda pcb that is mounted on the back of the mechanism assy. I have been just replacing the loading motor brackett assy and the pre-mda pcb to cure the problem for my customers that are under warranty. Let me know if you need any parts or any further help. Rex

Reply

Share |
1 comment

    Hi there Rex thanks heaps for your reply - I have since discovered that the cam is still under warranty - unbeknowns to me we purchased an extended warrant that I thought had already expired but no it hasnt - what a bonus !! so cam has gone in for repairs to a place in Brisbane - with a bit of luck the problem will be fixed permanently thanks again Jenny

    Reply




  