Re: jvc model gr-d90u condensation problem

JB38 Posted Aug 02, 2010, in response to:Joseph Stanton

Initial stage of the dew sensor cleaning procedure sent, should this fail to cure the problem then full disabling instructions will be sent, this containing approx nine JPEG attachments for illustration purposes. Although anyone contemplating this task is strongly advised to observe the under mentioned, the content of which cannot be classed as being exaggerated in any way! --------------------------------------------------------------------------- Please note that anyone requesting this info must "NOT" choose to hide their e-mail address as the info is complex with attachments and has to go to a "DIRECT" e-mail address which cannot be done if its hidden. It should be pointed out that the info is really in two stages the first being the dew sensor cleaning procedure, however should this procedure fail then the only option left is the second and more complex task of disabling the dew sensor circuit. ----------------------------------------------------------------------------- - AN IMPORTANT POINT CONCERNING THE MODIFICATION - The latter instructions given (disabling info) is really aimed at technically minded people of a "practical" hands-on type who are acquaint at working on small electro-mechanical devices of a precision nature or who have a flair for this sort of thing, and so in the interests of not making the situation any worse I would strongly advise anyone who does not really consider themselves as coming into that category NOT to attempt this work, as it involves separating the case and the unscrewing the main circuit board to gain access to the board below it, this requiring the disconnection of ribbon cables etc, it is also necessary to carry out the precision soldering of two "very" narrowly spaced PCB pins so the possession of a fine tipped soldering iron is also absolutely essential plus of course the skill to use same. Taking the above into consideration the qualification mentioned is really a MUST!! It should be emphasised that there are "NO" shortcuts into permanently getting over this problem other than what's been aforementioned, as if the "no dismantling" dew sensor cleaning procedure doesn't help but the "partial dismantling" memory reset "does", even this can only really be adopted as a stop gap measure as the CPU could lock up again at some point in time and indeed in many cases does exactly that!

Reply

Share |
0 comments



  


© 2001-2012 - Pechorin's - Contact Us - Report a bug

Pechorin's does not take responsibility for the content of the messages published in the Forum.

RSS feed