Eric Posted Jun 09, 2010

Error 6, unit in safegaurd mode, detach and reatch battery or unplug dc cord

my cam stoped working and i dont know why, all i get now is the flashing error 6 message, i follow the instructions and it still doesnt work

Reply

Share |
2 comments

    Re: JVC GR-D347u

     Eric Posted Jun 10, 2010

    ok, yea that makes sense cause there was a tape in it te be gain with, now when i put a tape in the spindles or spindle does not spin, causing the cam to eat tapes, i took the case off to maybe clease out and around the spindles but i dont know really what i was doing, is there an easier fix or dignostic

    Reply

    Re: JVC GR-D347u

     JB38 Posted Jun 10, 2010

    This fault indication is associated with the capstan not communicating with the system controller, and if a tape was in the device when this happened it could be that the tape in the cassette has turned that tight it has stopped the capstan spindle from turning and so a check should be made on this, that is should a tape actually be in the device!! However if no tape is installed then you will have to verify if the spindle can still turn, as if it doesnt then no pulses will be fed back into the system controller which will trigger E-06. If everything does turn then it requires the casing to be removed for a more detailed inspection to determine where the origin of the fault is.