PECHORIN'S home   account   archive   eshop   globalmediapro
.
.


Post new message


Home | Previous message

Re: E04 & safe mode

steve Posted Jun 07, 2010, in response to:Simbarashe

EMERGENCY TAPE EJECT / DOOR OPEN PROCEDURE. This procedure should release to cassette holder door, although of course dependant on the reason for the fault in the first place!, if however the procedure fails its likely because the mechanism is jammed which will necessitate separating the camcorder case to gain access to the mechanism. First take the battery out, and while its out switch the camcorder to "M". Next "HOLD AND KEEP HOLDING" the eject button whilst you reinsert the battery, if you are lucky the tape will eject as soon as the battery is reinstalled due to this action by-passing the "fault located - shut down mechanism" command that is sent from the sensors logic control circuit to the mechanism, i.e: the sensors logic control circuit cannot trigger a shut down signal if there is no power to it, and depending on your luck when you reinstall the battery and power is restored your eject command can sometimes take the lead over the sensors signal being acted upon by the logic control. (The aforementioned procedure may of course require more than one attempt with any subsequent attempts with the power switch on "A" rather than "M")

Reply

Share |
0 comments



  


© 2001-2012 - Pechorin's - Contact Us - Report a bug

Pechorin's does not take responsibility for the content of the messages published in the Forum.

RSS feed