PECHORIN'S home account archive eshop globalmediapro |
|
HomeJVC GR-D91U Condensation Error..had fixed by JVC once... I have a JVC GR-D91U "Condensation Error" problem. It was fixed by JVC Service and Repair once for over $100, and worked briefly. It is now back and I am looking to either fix it or buy a new camera. JVC wants me to ship it in again for another evaluation at $65. Any help would be appreciated.
1 comment
Dew sensor cleaning info sent via DIRECT e-mail, if this doesnt work then you have no option but to carry out the sensor disabling procedure. Anyone contemplating should note the undermentioned. ------------------------------------------------------------- It should be pointed out that the info is really in two stages the first being the dew sensor cleaning procedure, however should this procedure fail then the only option left is the second and more complex task of disabling the dew sensor circuit. Anyone thinking on this should please observe the undermentioned!!. -------------------------------------------------------------- - AN IMPORTANT POINT CONCERNING THE MODIFICATION - The instructions given are really aimed at technically minded people of a practical hands-on nature and who are acquaint at working on small precision electro-mechanical devices or who have a flair for this sort of thing, and so in the interests of not making the situation any worse I would strongly advise anyone who does not really consider themselves as coming into that category "NOT" to attempt this work, as it not only involves case separation but the disconnecting of two ribbon cables for accessing under the main PCB, it is also necessary to carry out the precision soldering of two "very" narrowly spaced PCB pins so a quality fine tipped soldering iron is also absolutely essential, plus of course having good soldering skills to use same. Taking the above into consideration the qualification mentioned is really a MUST!! It should be emphasised that there are "NO" shortcuts into permanently getting over this problem other than what's been aforementioned, as if the "no dismantling" dew sensor cleaning procedure doesn't help but the "partial dismantling" memory reset "does", even this can only really be adopted as a stop gap measure as the CPU could lock up again at some point in time and indeed in many cases does exactly that! |
|