PECHORIN'S home   account   archive   eshop   globalmediapro
.
.


Post new message


Home

JVC GR-D20E (model D20EY)

Eaglepmj Posted Jan 25, 2010

JVC D20E-Condensation Error - a permanent cure to disable the sensor would be appreciated

I would very much appreceate your help with solving the condence problem, so I would like to recive your instructions to bypass the condensation sensor for my unit. Model: JVC D20E (sub:D20EY) Thanks Eaglepmj

Reply

Share |
1 comment

    Re: JVC GR-D20E (model D20EY)

     JB38 Posted Jan 25, 2010

    Full info sent as requested, this having approx 9 JPEG's for illustration purposes. ------------------------------------------------------------------------------ Please note that anyone requesting this info must "NOT" choose to hide their e-mail address as the info is complex with attachments and has to go to a "DIRECT" e-mail address which cannot be done if its hidden. It should be pointed out that the info is really in two stages the first being the dew sensor cleaning procedure, however should this procedure fail then the only option left is the second and more complex task of disabling the dew sensor circuit. Anyone thinking on carrying out this mod is strongly advised to observe the undermentioned. -------------------------------------------------------------------------------- - AN IMPORTANT POINT CONCERNING THE MODIFICATION - The instructions given are really aimed at technically minded people of a "practical" nature who are acquaint at working on smaller electro-mechanical devices of a precision nature or who have a flair for this sort of thing, and so in the interests of not making the situation any worse I would strongly advise anyone who does not really consider themselves to come into that category NOT to attempt this work, as it involves separating the case and the unscrewing the main circuit board to gain access to the board below it, this requiring the disconnection of ribbon cables etc, it is also necessary to carry out the precision soldering of two "very" narrowly spaced PCB pins so the possession of a fine tipped soldering iron is also absolutely essential! Taking the above into consideration the qualification mentioned is really a MUST!! It should be emphasised that there are "NO" shortcuts into permanently getting over this problem other than what's been aforementioned, as if the "no dismantling" dew sensor cleaning procedure doesn't help but the "partial dismantling" memory reset "does", even this can only really be adopted as a stop gap measure as the CPU could lock up again at some point in time and indeed in many cases does exactly that!

    Reply




  


© 2001-2012 - Pechorin's - Contact Us - Report a bug

Pechorin's does not take responsibility for the content of the messages published in the Forum.

RSS feed