Re[3]: Error Codes Assistance

Assistance
- 18th Jan 2009 11:18

1). U10 Dew formation
Wait until the indication disappears.
2). H01 After cylinder lock is detected, the cylinder does not start rotating again even after tape unloading.
Check the cylinder-motor drive circuit.
3). H02 Cassette tape is not wound up during tape unloading except Eject mode.
Check the capstan-motor drive circuit.
4). F03 Mechanism locks during mode transition except Eject mode.
1. Check the loading-motor drive circuit.
2. Check the mechanism phase alignment.
3. Check the Mode Switch.
5). F04 Mechanism lock during tape unloading.
1. Check the loading-motor driveї circuit.
2. Check the mechanism phase alignment.
6). F05 Cassette tape is not wound up during tape unloading in Eject mode.
1. Check the capstan-motor drive circuit.
2. Check the Supply/Take-up reel pulse.
7). F06 Mechanism locks after tape unloading in Eject mode.
1. Check the loading-motor drive circuit.
2. Check the mechanism phase alignment for Cassette Holder Unit.
8). F09 No serial clock transmission between IC6001 and IC7501.
Check the serial clock circuit.