PECHORIN'S home   account   archive   eshop   globalmediapro
.
.


Post new message


Home | First message in thread | Previous message

Re[3]: JVC service or questions

george Posted Oct 02, 2006, in response to:Daries

The orignal fix that I mentioned used a 35V capacitor - that was the OEM design. My TV went out again after about a year. I replaced the cap with two 50V caps in parallel (to get the same capacitance value as he original design) and have not had any trouble since then. If yours goes out again - beef up the voltage handling of the caps. seems there is an inrush of current that may be too high for this cap (a poor design) George

Reply

Share |
1 comment

    Re[4]: JVC service or questions

     Paul Posted May 17, 2007

    While there was probably no harm in putting two capacitors in parallel, this is not the same capacitance. It is double the capacitance. Using a 50V unit accomplishes your goal of increasing the service factor.

    Reply




  