11=warning of increase of panel high voltage
12=warning of decrease of panel high voltage
21=warning of increase of panel middle voltage
22=warning of decrease of panel middle voltage
31=warning of increase of temperature at the power supply block in the top of the panel
39=power shut down due to increase in temperature at the power supply block at the top of the panel
A1=warning of increase in temperature at the center of the top of the panel
A9=power shut down due to increase of the temp. at the center at the top of the panel
41=warning of increase in temp.at the input/output block of the top of the panel
49=power shut down due to increase of temp.at the input/output block of the top of the panel
51=warning of stopage of air intake fan-1 of the power supply block
52="""""""""""""""""""""""""""""""""fan-2"""""""""""""""""""""""""
53""""""""""""""""""""of the fan input/output block of the panel top
54=""""""""""""""""""""of the fan at the center """"""""""""""""""""
55=""""""""""""""""""""""'"""""""power supply"""""""""""""""""""""""""
58=failure of the fan drive circuit
79=power shut down due to decrease of digital 5 volts
81=eeprom id error
82=eeprom write error
83=eeprom read error
85=eeprom is defective
91=communication with scan converter is defective
98=failure that voltage does not decrease at power off
99=panel is defective
b1=warning of intialization of time data due to watch control error
b2=decrease of the backup power voltage for watch
b3=oscillator for watch is defective
f1=warning of increase of ambient temp.
Now wasn't that fun
Tim
Reply