PECHORIN'S home   account   archive   eshop   globalmediapro
.
.


Post new message


Home | First message in thread | Previous message

Re: Re: Panasonic PV-L600D

Mike Posted Dec 20, 2004, in response to:Mike

I just worked on a PV-L680. On this unit the Dew sensor is located on a flex cable on the handle side of the unit just above the nylon strap. Looks like shorting the sensor out will defeat the Dew Detect sensor cirtcuit but unfortunely a solder iron will melt thye flex cable when trying to attach a jumper. Most likely fix will be a replacement cable if the vendor has fixed the root design error in the Dew sensor circuit(maybe by changing the value of the sensor itself). Otherwise, looking at the magnitude of the error, replacing the flex cable with will at best only delay the problem.

Reply

Share |
2 comments



  


© 2001-2012 - Pechorin's - Contact Us - Report a bug

Pechorin's does not take responsibility for the content of the messages published in the Forum.